Assessing the reproducibility and predictive value of objective cough measurement for successful withdrawal of invasive ventilatory support in adult patients

Fabio Varón-Vega (Autor Corresponsal), Adriana Rincón (Estudiante de maestría), Luis F. Giraldo-Cadavid (Tercer Autor), Eduardo Tuta-Quintero (Estudiante de maestría), Jonathan Palacios (Quinto Autor), Stephanie Crevoisier, Diana C. Duarte, Marcela Poveda, Laura Cucunubo, Pablo Monedero

Producción científica: Contribución a una revistaArtículorevisión exhaustiva

1 Cita (Scopus)

Resumen

Background: Utilizing clinical tests, such as objective cough measurement, can assist in predicting the success of the weaning process in critically ill patients. Methods: A multicenter observational analytical study was conducted within a prospective cohort of patients recruited to participate in COBRE-US. We assessed the capability of objective cough measurement to predict the success of the spontaneous breathing trial (SBT) and extubation. Intra- and inter-observer reproducibility of the cough test and was evaluated using the intraclass correlation coefficient (ICC) and Cohen’s weighted kappa. We used receiver operating characteristic curves (ROC-curve) to evaluate the predictive ability of objective cough measurement. Results: We recruited 367 subjects who were receiving invasive mechanical ventilation. A total of 451 objective cough measurements and 456 SBTs were conducted. A significant association was found between objective cough measurement and successful SBT (OR: 1.68; 95% CI 1.48–1.90; p = 0.001). The predictive capability of the objective cough test for SBT success had a ROC-curve of 0.58 (95% CI: 0.56–0.61). Objective cough measurement to predict successful extubation had a ROC-curve of 0.61 (95% CI: 0.56–0.66). The intraobserver reproducibility exhibited an ICC of 0.94 (95% CI: 0.89–0.96; p < 0.001), while the interobserver reproducibility demonstrated an ICC of 0.72 (95% CI: 0.51–0.85; p < 0.001). The intraobserver agreement, assessed using Cohen’s weighted kappa was 0.94 (95% CI: 0.93–0.99; p < 0.001), whereas the interobserver agreement was 0.84 (95% CI: 0.67 − 0.10; p < 0.001). Conclusions: The objective measurement of cough using the method employed in our study demonstrates nearly perfect intra-observer reproducibility and agreement. However, its ability to predict success or failure in the weaning process is limited.

Idioma originalInglés
Número de artículo218
PublicaciónBMC Pulmonary Medicine
Volumen24
N.º1
DOI
EstadoPublicada - dic. 2024

Focos Estratégicos

  • Vida Humana Plena (Vita)​

Clasificación de Articulo

  • Artículo completo de investigación

Indexación Internacional (Artículo)